1
ETLus
Listed
Patents Pending. All Rights Reserved.
Photoelectronic Smoke Detector with
Built-in Wireless Transmitter
Model # SD4-SS
INSTALLATION AND
OPERATION MANUAL
Zobrazit stránku 0
1 2 3 4 5 6 ... 27 28

Shrnutí obsahu

Strany 1 - OPERATION MANUAL

1ETLus ListedPatents Pending. All Rights Reserved.Photoelectronic Smoke Detector with Built-in Wireless TransmitterModel # SD4-SSINSTALLATION ANDOPERA

Strany 2

10as long as no other door or other obstructions block the path of smoke to the detector.• In rooms with sloped, peaked, or gabled ceilings, mount de

Strany 3

11This detector will provide maximum protection when installed in compliance with the National Fire Protection Association (NFPA). Stan

Strany 4 - Inc., Quincy, MA 02269.)

12as kitchens, in garages where there are particles of combustion from vehicle exhausts, near furnaces, hot water heaters, or gas space heaters. Inst

Strany 5

13• In damp or very humid areas, or next to bathrooms with showers. The moisture in humid air can enter the sensing chamber as water vapor, and will

Strany 6

14General InformationBefore installing detectors, please thoroughly read these installation instructions and NFPA 72, which provides detailed informat

Strany 7

15the detector to automatically maintain proper operation at factory calibrated detection levels, even when sensitivity is altered due to the presence

Strany 8

16Two LEDs and a sounder on the detector provide local visual and audible indication of the detector’s status:Table 1: Detector LED ModesGreen LED Red

Strany 9 - Acceptable location

17every 10 seconds. If the detector is in need of maintenance because its sensitivity has shifted outside the listed limits, the red LED blinks once e

Strany 10 - Horizontal

18batteries maybe purchased from a local hardware store.Battery Installation and ReplacementTo replace the battery:1. Remove the detector from its mo

Strany 11

19ProgrammingThe smoke detector is pre-programmed at the factory.Address Switch SettingsThe Silent Call system is digitally encoded. All Silent Call r

Strany 12 - Incorrect

2What smoke detectors can do:Smoke detectors are designed to provide early warning of developing res at a reasonable cost. They monitor the a

Strany 13

20that you MUST remove the batteries rst or the switch setting will not take effect.3. Locate the address switch on the transmitter circuit board th

Strany 14

21the following steps:1. Once a suitable location has been determined, install the mounting base on the ceiling or on the wall (if local ordinances p

Strany 15

22Dust Covers are an effective way to limit the entry of dust into the smoke detector sensing chamber during construction. However, they may not compl

Strany 16 - Table 1: Detector LED Modes

23diameter of 0.18 inch (the detector will trigger and then the smoke detector will go into alarm thus sending a transmitting signal to the receiver.

Strany 17

24If the detector is within the listed sensitivity limits, the LED on the detector should blink once per second and the horn should sound within 3 sec

Strany 18

25NOTE: Power must be removed from the detector before performing maintenance of any kind by removing the detector’s battery.1. To ensure proper powe

Strany 19 - Wireless Smoke Detector

26chamber and turning it clockwise until it snaps into place.8. Reinstall the battery into the battery compartment noting proper orientation.9. Rein

Strany 20

27What to do in case of re• Don’t panic; stay calm. Follow your family escape plan.• Get of the house as quickly as possible. Don’t stop to get dre

Strany 21

28SpecicationsPower Source: One 3-volt CR123A Lithium Battery (included). (Replace with Duracell DL123A, Panasonic CR123A)Height: 2.3 inches (58 mm

Strany 22

3Smoke detectors may not sense res that start where smoke cannot reach the detectors such as in chimneys, in walls, on roofs, or on the other side of

Strany 23 - Recessed Test Switch Opening

4can sense every kind of re every time. In general, detectors may not always warn you about red caused by carelessness and safety hazards like

Strany 24

5minimum recommendations is one detector on each level of a building and one in every sleeping area. See how this recommendation applies in the gures

Strany 25

6Figure 1: recommended smoke detector protection for single-oor residence with only one sleeping area.DiningRoomKitchenBedroomBedroomBedroomLiving Ro

Strany 26

7Smoke detectors for minimum protectionSmoke detectors for more protectionBedroomBedroomBedroomLivingRoomKitchenBasementGarageFigure 3: recommended

Strany 27

8• Put a smoke detector inside every bedroom where someone sleeps with the door closed. Smoke could be blocked by the closed door, or the alar

Strany 28 - Specications

9Best locationAcceptable locationDeadAirSpaceBest incenter ofceilingNo closer than 4 inch(10 cm) from side wallMount on wall at least 4 inch(10 cm) fr